ΠΕΤΡΟΣ ΣΜΑΧΛΙΟΥ FRCS FEBO
ΑΣΦΑΛΕΙΑ ΟΧΙ ΚΑΛΗ ΕΠΑΝΑΛΗΨΙΜΟΤΗΤΑ AΡΓΗ ΕΠΕΜΒΑΣΗ ΠΟΝΟΣ HAZE ΥΠΕΡΔΟΣΟΛΟΓΙΑ ΔΥΣΑΝΕΞΙΑ ΣΤΟΥΣ ΦΑΚΟΥΣ ΕΠΑΦΗΣ ΑΡΓΗ ΕΠΟΥΛΩΣΗ ‘ΟΡΙΑΚΑ΄ ΠΕΡΙΣΤΑΤΙΚΑ
AΠΟΞΕΣΗ ΕΠΙΘΗΛΙΟΥ 9,00χιλ. ΡΙΒΟΦΛΑΒΙΝΗ 0,1% ΚΑΘΕ 3 ΛΕΠΤΑ ΓΙΑ ΜΙΣΗ ΩΡΑ ΑΚΤΙΝΟΒΟΛΗΣΗ ΓΙΑ 30 ΛΕΠΤΑ ΒΑΖΟΝΤΑΣ ΡIBOFLABINH ΚΑΘΕ 3 ΛΕΠΤΑ ΦΑΚΟΣ ΕΠΑΦΗΣ ΣΤΑΓΟΝΕΣ ΚΟΡΤΙΖΟΝΗΣ ΚΑΙ ΑΝΤΙΒΙΟΤΙΚΟΥ
ΕΙΝΑΙ ΑΣΦΑΛΗΣ (ενδοθηλιο, κερατοκυτταρα, φακος κα) ΕΙΝΑΙ ΓΡΗΓΟΡΗ ΕΙΝΑΙ ΑΠΟΤΕΛΕΣΜΑΤΙΚΗ (και σε βαθος χρονου) ΕΧΕΙ ΕΠΑΝΑΛΗΨΙΜΟΤΗΤΑ (ειναι στανταρισμενη) ΔΕΝ ΕΧΕΙ ΜΕΤΕΓΧΕΙΡΗΤΙΚΑ ΠΡΟΒΛΗΜΑΤΑ
SpeedSpeed Typical UVA Light source in current use Avedro KXL System 3 mW/cm 2 30 min exposure 30 mW/cm 2 3 min exposure 5J/cm 2 Same Energy on Cornea MA-00057, Rev. A
Keratocyte and Endothelial Cell Viability Endothelial cells show similar or better cell viability at higher irradiance for shorter time vs. lower irradiance for a longer time SafetySafety Courtesy of Prof. John Marshall 3mW/cm 2 – 30 Min 30mW/cm 2 – 3 Min *Optical Density MA-00057, Rev. A
ΔΟ : -2,00 / -1,25 x 103 AO: -1,50 / -1,50 x 75 Παχυμετρία : 550μ, αμφω
ΔΕΞΙ ΜΑΤΙ : transepithelial PRK & PRK-Xtra ΑΡΙΣΤΕΡΟ ΜΑΤΙ :transepithelial topoguited PRK& AVEDRO CXL
Lasik (PRK) Xtra …Strengthening Corneas Weakened by Lasik (or PRK) 9 Efficacy:Lasik Xtra returns corneas to their original pre-surgical strength Speed: 1.25 minute UVA exposure with higher power Safety: 1 minute soak time Predictability: Uniform Beam Profile MA-00057, Rev. A
High performance Cross-linking Protocol: Keratoconus & Post-Lasik Ectasia Speed: Accelerated 3 minute UVA exposure at 30 mW/cm 2 Safety: 5-10 minute time soak time (depending on corneal thickness) Predictability: Uniform beam profile (Consistent energy delivered across the cornea with superior depth of focus) MA-00057, Rev. A
Corneal Biomechanics Corneal Young’s Modulus/MPa SpeedSpeed Courtesy of Prof. John Marshall MA-00057, Rev. A UVA Cross-linked 30 mW/cm² Avedro Others UVA Cross-linked 3 mW/cm²
ΔΕΞΙΟΣ ΟΦΘΑΛΜΟΣ: +0,25 / - 0,50Χ 140 ΑΡΙΣΤΕΡΟΣ ΟΦΘΑΛΜΟΣ: +0,25 BCVA: 20/20 BEs
A Lasik Flap Weakens the Cornea by up to 30% Courtesy of Prof. John Marshall Flap Depth Corneal Weakening MA-00057, Rev. A
Equi-dose Extensiometry: Stress/Strain There are no statistically significant biomechanical differences when Equi-dosing high UVA with shorter exposure time Adapted from Krueger, Spoerl, Herekar, Rapid vs. Standard Collagen CXL with Equivalent Energy Dosing. Original online presentation link: linking SpeedSpeed MA-00057, Rev. A
Endothelium Safety Concerns are Related to … UVA & Riboflavin Interaction, NOT UVA Alone SafetySafety Two important considerations when performing cross-linking: 1.Have enough riboflavin in the anterior stroma for cross-link formation 2. Limit the UVA absorption by the riboflavin adjacent to the endothelium KXL accelerated crosslinking at μm has the same relative absorption as standard cross- linking at μm CXL: 30 minute pre-soak; 30 minute 3 mW/cm ² KXL: 5 minute pre-soak; 3 minute 30 mW/cm ² KXL: 10 minute pre-soak; 3 minute 30 mW/cm ² MA-00057, Rev. A
PredictabilityPredictability 9 mm Aperture Bowman’s Endothelium 3 mW/cm 2 typical UVA light in current use Cool edges provide no cross-linking Center to edge beam uniformity insures consistent results 30 mW/cm 2 KXL System MA-00057, Rev. A
Current Standard of Care: Ophthalmologists perform negative prophylaxis by rejecting some % of lasik patients Positive Prophylaxis is Possible With Lasik Xtra Ineligible for Lasik due to potential corneal weakness All potential patients who desire Lasik With Lasik Xtra: Because cross-linking increases corneal strength, positive prophylaxis with cross-linking can make many of these patients eligible for Lasik Ineligible Eligible EfficacyEfficacy MA-00057, Rev. A
ΤΟ KXL EINAI ENA KAINOYΡΓΙΟ ‘ΕΡΓΑΛΕΙΟ’ ΣΤΑ ΧΕΡΙΑ ΤΟΥ ΚΛΙΝΙΚΟΥ ΟΦΘΑΛΜΙΑΤΡΟΥ ΥΠΟΣΧΕΤΑΙ ΜΕΓΑΛΥΤΕΡΗ ΑΣΦΑΛΕΙΑ ΚΑΛΥΤΕΡΗ ΕΠΑΝΑΛΗΨΙΜΟΤΗΤΑ ΤΟ LASIK Xtra ΠΡΟΣΦΕΡΕΙ ΜΕΓΑΛΥΤΕΡΗ ΑΣΦΑΛΕΙΑ ΣΕ ΟΡΙΑΚΕΣ ΠΕΡΙΠΤΩΣΕΙΣ ΜΕΤΑΤΡΕΠΕΙ CAN’T DO ΠΕΡΙΠΤΩΣΕΙΣ ΣΕ CAN DO ΕΙΝΑΙ ‘ΒΟΛΙΚΟ’ ΓΙΑΤΙ ΕΙΝΑΙ ΓΡΗΓΟΡΟ ΕΧΕΙ ΚΑΛΗ ΕΡΓΟΝΟΜΙΑ ΑΛΛΑ ΜΟΝΟ Ο ΧΡΟΝΟΣ ΘΑ ΔΕΙΞΕΙ